Описание

  • Housing G1
  • 2-stage function
  • Kit without connection cable
2-stage functionEnabling function is active in the second stage (pressed position). When the button is released, the enabling is removed (see function sequence).As per VDI 2854, a device comparable to an EMERGENCY STOP device must be fitted! Switching element
212NO+1NC
Dimension drawing 21 Dimension drawing21 Technical dataApprovals Mechanical values and environment
Material Plastic
Weight
Net 0,25 kg
Ambient temperature -5 ... 50 °C
Degree of protection IP65
Mechanical life
Position 1-2-1 0,1 x 106
Switching principle Slow-action contact element
Number of NC contacts 1
Number of NO contacts 2
Connection Tab connector 2.8 x 0.8 IEC 760, cable O 3.5...8.0 mm
Electrical connection ratings
Rated conditional short-circuit current 100 A
Utilization category according to EN 60947-5-1
AC-15 4A 230V
DC-13 3A 24V
Short circuit protection according to IEC 60269-1 4A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Degree of contamination (external, according to EN 60947-1) 3
Switching characteristics 2-stage enabling switch
Other
In compliance with 60947-5-1
''